D&R AXUM Manuel d'utilisateur Page 45

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 115
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 44
Installing/Servicing the Airlab
Airlab from D&R Phone +31 294 418014, email: [email protected] Page 45
NOTE:
Wiring a tuner needs special attention. If the tuner is "cabled", the coax antennae cable will
probably cause a ground loop. A H.F. transformer must separate the antenna input of the tuner.
Ask your dealer or any radio shop for details.
*IMPORTANT*
SAFETY PRECAUTION - All 'outside' connections to the Airlab, even from the same building, must be
connected via a transformer. This avoids the possibility of ground loops and 'hums'. The shielding must be
connected to the source side.
In areas with a strong H.F. interference, it is wise to connect the other side of the shielding through a 0.1
uF/250 Volt ceramic capacitor. The capacitor will not affect the audio, but will reduce H.F. signals.
Servicing the Airlab
A. Disconnect the mains supply.
B. Remove the power cable from the back of the console.
C. Remove the back panel of the meter hood.
D. Unscrew the channel module bolts.
E. Now lift the channel up at the fader section, and then the other side. Carefully lift
the module until you see three connectors mounted to ribbon (flat) cables.
F. On the PCB part of the connector you will see two ejectors with which to eject the
cable header.
Installing the Channel Module
A. Plug the three ribbon cable connectors into the PCB connector, ensuring that the
ejectors are securely replaced.
B. Slowly put the module down into the chassis starting from the rear.
C. Tighten all screws and reconnect the channel.
Servicing the Master Section
A. Disconnect the Airlab from the mains supply.
B. Remove all holding screws.
C. Lift the master section starting from the fader's side.
D. Remove the connector to the power PCB.
E. Lift the section upwards until you are able to remove the ribbon cable from the PCBs.
F. Reverse this procedure to re-mount the master section.
Vue de la page 44
1 2 ... 40 41 42 43 44 45 46 47 48 49 50 ... 114 115

Commentaires sur ces manuels

Pas de commentaire