How to program the Airlab
Airlab from D&R Phone +31 294 418014, email: [email protected] Page 52
REMOTE CUE POSSIBLE IN LINE A MODE
To enter the next programming possibility you simply hit the
DOWN button again and you will see a new item. See on the
right what the LCD shows:
This option allows you to set if the CUE must be activated by
an incoming remote on one or more modules, when set in
Line A input mode.
HOW TO PROGRAM
The SELECT switches in the modules have a dual function. They select the module you are programming
and at the same time you can toggle between the active and not active setting. This is a very quick way of
programming this function. If you have already programmed several modules, the moment you enter this
menu again the LED’s located near the SELECT switch will light up on the modules that are capable of
activating the CUE by a remote switch.
REMOTE CUE POSSIBLE IN LINE B MODE
To enter the next programming possibility you simply hit the
DOWN button again and you will see a new item. See on the
right what the LCD shows:
This option allows you to set if the CUE must be activated by
an incoming remote on one or more modules, when set in
Line B input mode.
HOW TO PROGRAM
The SELECT switches in the modules have a dual function. They select the module you are programming
and at the same time you can toggle between the active and not active setting. This is a very quick way of
programming this function. If you have already programmed several modules, the moment you enter this
menu again the LED’s located near the SELECT switch will light up on the modules that are programmed
to activate the CUE by a remote switch in line B input mode.
REMOTE CUE POSSIBLE IN MIC MODE
To enter the next programming possibility you simply hit the
DOWN button again and you will see a new item. See on the
right what the LCD shows:
This option allows you to set if the CUE must be activated by
an incoming remote on one or more modules, when set in
Mic input mode. This option is necessary for COUGH/COMM.
Not available for Telco Module.
HOW TO PROGRAM
The SELECT switches in the modules have a dual function. They select the module you are programming
and at the same time you can toggle between the active and not active setting. If you had already
programmed several modules, the moment you enter this menu again the LED’s located near the SELECT
switch will go on, on those modules that are capable of activating the CUE by a remote switch when the
MIC input is selected.
LineA Rem. Cue?
Toggle by SELECT
LineB Rem. Cue?
Toggle by SELECT
Mic. Rem. Cue?
Toggle by SELECT