CobraNet™ input/output card
The CobraNet™ card holds two RJ45 connectors that
carry CobraNet data over Ethernet (level 2).
CN A should be connected to your audio network.
CN B may be used for a redundant connecon.
Ulizing the CobraNet™ connecon, you can send and
receive mulple audio channels. The number of audio
channels is 16 send and receive mono channels.
For each signal received from CobraNet
you have digital control over:
Level
Phase inverse
Roung:
- Le to Le
- Right to Right
- Mono to Le
- Mono to Right
- Right to Le
- Le to Right
For each signal sent to CobraNet™ you
have digital control over:
Level
Phase inverse
Roung
- Le to Le
- Right to Right
- Mono to Le
- Mono to Right
- Right to Le
- Le to Right
Dimming
Talkback to the output
Total mute.
With D&R’s CobraNet™ Manager Soware, you can visualize
and control the CobraNet™ audio network. Included with this
card is a light version of CobraNet™ Management soware